Development and evaluation of a Loop Mediated Isothermal Amplification (LAMP) technique for the detection of hookworm (Necator americanus) infection in fecal samples

Show simple item record

dc.contributor.author ROBERT MUGAMBI MURIUKI
dc.contributor.author Eric L Agola, Ibrahim N Mwangi, Johnson Kinyua, Esther Andia Shiraho, Gerald M Mkoji
dc.date.accessioned 2025-11-12T08:40:41Z
dc.date.available 2025-11-12T08:40:41Z
dc.date.issued 2015
dc.identifier.uri https://doi.org/10.1186/s13071-015-1183-9
dc.identifier.uri http://repository.kemri.go.ke:8080/xmlui/handle/123456789/1698
dc.description.abstract Background Hookworm infection is a major concern in sub-Saharan Africa, particularly in children and pregnant women. Necator americanus and Ancylostoma duodenale are responsible for this condition. Hookworm disease is one of the Neglected tropical diseases (NTDs) that are targeted for elimination through global mass chemotherapy. To support this there is a need for reliable diagnostic tools. The conventional diagnostic test, Kato-Katz that is based on microscopic detection of parasite ova in faecal samples, is not effective due to its low sensitivity that is brought about mainly by non-random distribution of eggs in stool and day to day variation in egg output. It is tedious, cumbersome to perform and requires experience for correct diagnosis. LAMP-based tests are simple, relatively cheap, offer greater sensitivity, specificity than existing tests, have high throughput capability, and are ideal for use at the point of care. Methods We have developed a LAMP diagnostic test for detection of hookworm infection in faecal samples. LAMP relies on auto cycling strand displacement DNA synthesis performed at isothermal temperature by Bst polymerase and a set of 4 specific primers. The primers used in the LAMP assay were based on the second Internal Transcribed Spacer (ITS-2) region and designed using Primer Explorer version 4 Software. The ITS-2 region of the ribosomal gene (rDNA) was identified as a suitable target due to its low mutation rates and substantial differences between species. DNA was extracted directly from human faecal samples, followed by LAMP amplification at isothermal temperature of 63 °C for 1 h. Amplicons were visualized using gel electrophoresis and SYBR green dye. Both specificity and sensitivity of the assay were determined. Results The LAMP based technique developed was able to detect N. americanus DNA in faecal samples. The assay showed 100 % specificity and no cross-reaction was observed with other helminth parasites (S. mansoni, A. lumbricoides or T. trichiura). The developed LAMP assay was 97 % sensitive and DNA at concentrations as low as 0.4 fg were amplified. Conclusion The LAMP assay developed is an appropriate diagnostic method for the detection of N. americanus DNA in human stool samples because of its simplicity, low cost, sensitivity, and specificity. It holds great promise as a useful diagnostic tool for use in disease control where infection intensities have been significantly reduced. en_US
dc.language.iso en en_US
dc.publisher Parasit Vectors en_US
dc.subject Loop mediated isothermal amplification, ITS-2, Necator americanus, Kato-Katz en_US
dc.title Development and evaluation of a Loop Mediated Isothermal Amplification (LAMP) technique for the detection of hookworm (Necator americanus) infection in fecal samples en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

  • Journals and Articles
    This is a collection of journals published by KEMRI Graduate School students, fulll access to the article can be access through the link provided.